Critical update
This update addresses a Com port mapping issue and a memory map issue.
This critical update is only for System 5000 TPU's that use the 5100 CPU board.
If you are unsure, check the TPU, the CPU board is as follows.

- 1. Down load and install vxWorks version 5.30 into your klein folder. Note, Windows may assign this file as a .txt file after it is down loaded. To check, open the Windows File Explorer and locate the downloaded file. Select Tools, Folder Options, View, and uncheck "Hide file extensions for unknown files". If there is a .txt extension added to the vxWorks file, then remove the extension by editing it with the rename function.
- 2. Add the following line to your startup.ini file
set INCLUDE_IPMC761 1
- 3. Move the connector from Com 1 to Com 2 on the top MVME 761-001 board in the TPU

|